sun 4800扩容CPU板.docx
《sun 4800扩容CPU板.docx》由会员分享,可在线阅读,更多相关《sun 4800扩容CPU板.docx(23页珍藏版)》请在冰豆网上搜索。
![sun 4800扩容CPU板.docx](https://file1.bdocx.com/fileroot1/2023-2/28/107babb1-e99e-4440-bc99-beaec12f90d8/107babb1-e99e-4440-bc99-beaec12f90d81.gif)
sun4800扩容CPU板
SUN4800扩容CPU板
1.升级准备
检查机房环境(包括当前设备供电系统、配置情况等等)记录系统关键信息(例如prtdiag-v、df–k等)
root@XXX#/usr/platform/sun4u/sbin/prtdiag-v
SystemConfiguration:
SunMicrosystemssun4uSunFire4800
Systemclockfrequency:
150MHz
Memorysize:
16384Megabytes
=========================CPUs===============================================
PortRunE$CPUCPU
FRUNameIDMHzMBImpl.Mask
---------------------------------
/N0/SB2/P0812008.0US-III+6.0
/N0/SB2/P1912008.0US-III+6.0
/N0/SB2/P21012008.0US-III+6.0
/N0/SB2/P31112008.0US-III+6.0
/N0/SB4/P01612008.0US-III+6.0
/N0/SB4/P11712008.0US-III+6.0
/N0/SB4/P21812008.0US-III+6.0
/N0/SB4/P31912008.0US-III+6.0
=========================MemoryConfiguration===============================
LogicalLogicalLogical
PortBankBankBankDIMMInterleaveInterleave
FRUNameIDNumSizeStatusSizeFactorSegment
----------------------------------------------------------------
/N0/SB2/P0/B0801024MBpass512MB8-way0
/N0/SB2/P0/B0821024MBpass512MB8-way0
/N0/SB2/P1/B0901024MBpass512MB8-way0
/N0/SB2/P1/B0921024MBpass512MB8-way0
/N0/SB2/P2/B01001024MBpass512MB8-way0
/N0/SB2/P2/B01021024MBpass512MB8-way0
/N0/SB2/P3/B01101024MBpass512MB8-way0
/N0/SB2/P3/B01121024MBpass512MB8-way0
/N0/SB4/P0/B01601024MBpass512MB8-way1
/N0/SB4/P0/B01621024MBpass512MB8-way1
/N0/SB4/P1/B01701024MBpass512MB8-way1
/N0/SB4/P1/B01721024MBpass512MB8-way1
/N0/SB4/P2/B01801024MBpass512MB8-way1
/N0/SB4/P2/B01821024MBpass512MB8-way1
/N0/SB4/P3/B01901024MBpass512MB8-way1
/N0/SB4/P3/B01921024MBpass512MB8-way1
=========================IOCards=========================
BusMax
IOPortBusFreqBusDev,
FRUNameTypeIDSideSlotMHzFreqFuncStateNameModel
-------------------------------------------------------------------------------------------------
/N0/IB6/P0PCI24A366661,0okpci-pci8086,b154.0/network(netw+pci-bridge
/N0/IB6/P0PCI24A366660,0oknetwork-pci108e,abba.20SUNW,pci-ce
/N0/IB6/P0PCI24A366661,0oknetwork-pci108e,abba.20SUNW,pci-ce
/N0/IB6/P0PCI24A366662,0okscsi-pci1000,b.7/disk(block)
/N0/IB6/P0PCI24A366662,1okscsi-pci1000,b.7/disk(block)
/N0/IB8/P1PCI29B533332,0oknetwork-pci100b,35.30SUNW,pci-ce
=========================ActiveBoardsforDomain===========================
PowerFaultHotPlugBoard
FRUNameLEDLEDLEDCond.
--------------------------------
/N0/SB2onoffoffok
/N0/SB4onoffoffok
/N0/IB6onoffoffok
/N0/IB8onoffoffok
=========================AvailableBoards/SlotsforDomain==================
PowerFaultHotPlugBoard/SlotBoard/Slot
FRUNameLEDLEDLEDConditionAssigned
---------------------------------------------
/SB0offoffoffEmptyyes
=========================HardwareFailures==================================
NoHardwarefailuresfoundinSystem
=========================HWRevisions=======================================
SystemPROMrevisions:
----------------------
OBP5.20.004/04/0617:
31
IOASICrevisions:
------------------
Port
FRUNameModelIDStatusVersion
-------------------------------------------
/N0/IB6/P0SUNW,schizo24ok4
/N0/IB6/P1SUNW,schizo25ok4
/N0/IB8/P0SUNW,schizo28ok4
/N0/IB8/P1SUNW,schizo29ok4
/N0/IB6/P0SUNW,sgsbbc24ok2
/N0/IB8/P0SUNW,sgsbbc28ok2
root@XXX#
:
SC>showplatform
DomainSolarisNodenameDomainStatusKeyswitch
--------------------------------------------------------------
A-PoweredOffoff
B-PoweredOffoff
C-PoweredOffoff
D-PoweredOffoff
Thesystemcontrollerisconfiguredtobeonanetwork.
WARNING:
Thelinkisdown!
Networksettings:
DHCP
LoghostforPlatform:
LogFacilityforPlatform:
local0
SNTPserver:
SNMPAgent:
disabled
ChassisDescription:
SunFire4800
ChassisContact:
ChassisLocation:
ACLforDomainA:
SB0SB2SB4IB6IB8
ACLforDomainB:
SB0SB2SB4IB6IB8
ACLforDomainC:
SB0SB2SB4IB6IB8
ACLforDomainD:
SB0SB2SB4IB6IB8
ChassisHostID:
83249c57
PROCRTUsinstalled:
0
PROCHeadroomQuantity:
0
PROCRTUsreservedfordomainA:
0
PROCRTUsreservedfordomainB:
0
PROCRTUsreservedfordomainC:
0
PROCRTUsreservedfordomainD:
0
SCPOSTdiagLevel:
min
SCFailover:
enabledandactive.
LogicalHostname:
Telnetservers:
Enabled
Idleconnectiontimeout:
Notimeout
Chassisisinsinglepartitionmode.
Frame:
0003ba:
4db01b(WedJul2913:
54:
16PDT2009)
FailLED:
OffServiceLED:
Off
FrameFanTrays
LeftTrayRightTray
State:
OKOK
PowerLED:
OnOn
FaultLED:
OffOff
ServiceLED:
OffOff
Speed:
SlowSlow
Temperature:
NormalNormal
Power:
OKOK
Fan0:
OKOK
Fan1:
OKOK
Fan2:
OKOK
FrameRTS
Rear/Left-OK,ConnectedtotheSystem
Rear/Right-OK
Front/Left-NotPresent
Front/Right-NotPresent
:
SC>showboards
SlotPwrComponentTypeStateStatusDomain
--------------------------------------
SSC0OnSystemControllerMainPassed-
SSC1OnSystemControllerSpare--
ID0OnSunFire4800Centerplane-OK-
PS0OnA153PowerSupply-OK-
PS1OnA153PowerSupply-OK-
PS2OnA153PowerSupply-OK-
FT0OnFanTrayLowSpeedOK-
FT1OnFanTrayLowSpeedOK-
FT2OnFanTrayLowSpeedOK-
RP0OnRepeaterBoard-OK-
RP2OnRepeaterBoard-OK-
/N0/SB2OnCPUBoardV2AssignedNottestedA
/N0/SB4OnCPUBoardV2AssignedNottestedA
/N0/IB6OnPCII/OBoardAssignedNottestedA
/N0/IB8OnPCII/OBoardAssignedNottestedA
:
SC>
:
SC>
当前使用了SB2和SB4,SB0槽位空闲
:
SC>
:
SC>console-da
ConnectedtoDomainA
DomainShellforDomainA
:
A>
:
A>
:
A>showdomain
DomainSolarisNodenameDomainStatusKeyswitch
--------------------------------------------------------------
A-PoweredOffoff
diag-level=default
verbosity-level=min
error-level=max
interleave-scope=within-board
interleave-mode=optimal
reboot-on-error=true
hang-policy=reset
OBP.use-nvramrc?
=true
OBP.auto-boot?
=
OBP.error-reset-recovery=
LoghostforDomainA:
LogFacilityforDomainA:
local0
SNMPAgent:
disabled
DomainDescription:
DomainContact:
ACLforDomainA:
SB0SB2SB4IB6IB8
PROCRTUsreservedfordomainA:
0
:
A>
:
A>
停止相关应用,并系统下执行init5关闭系统
2.关闭系统后进入domainA中,使用setkeyswitchoff掉电
:
A>setkeyswitchoff
ThiswillabruptlyterminateSolarisindomainA.
Doyouwanttocontinue?
[no]yes
Poweringboardsoff...
3.退到SC下使用poweroff关闭电源
:
A>disconnect
:
SC>poweroffall
/N0/SB2:
isalreadyoff
/N0/SB4:
isalreadyoff
/N0/IB6:
isalreadyoff
/N0/IB8:
isalreadyoff
RP0:
isalreadyoff
RP2:
isalreadyoff
PS0:
poweredoff
PS1:
poweredoff
Jul2913:
50:
26Platform.SC:
FT0,fanspeed,Off(4,0)
Jul2913:
50:
32Platform.SC:
FT1,fanspeed,Off(4,0)
Jul2913:
50:
38Platform.SC:
FT2,fanspeed,Off(4,0)
Jul2913:
50:
45Platform.SC:
CAUTION:
Physicallyremovingthelastpowersupplywillcausethesystemcontrollertolosepower.
PS2:
poweredoff
:
SC>
:
SC>poweroffgrid0
grid0:
poweredoff
4.将新CPU板安装在SB0插槽
5.使用poweron命令进行加电
:
SC>powerongrid0
Jul2914:
24:
54Platform.SC:
FT0,fanspeed,Low(4,1)
Jul2914:
25:
00Platform.SC:
FT1,fanspeed,Low(4,1)
Jul2914:
25:
09Platform.SC:
FT2,fanspeed,Low(4,1)
Jul2914:
25:
09Platform.SC:
/N0/SB0,hotplugstatus,SB0,moduleinserted(9,17)
grid0:
poweredon
:
SC>
:
SC>
:
SC>
:
SC>poweronall
PS0:
alreadyon
PS1:
alreadyon
PS2:
alreadyon
RP0:
poweredon
RP2:
poweredon
/N0/SB0:
poweredon
/N0/SB2:
poweredon
/N0/SB4:
poweredon
/N0/IB6:
poweredon
/N0/IB8:
poweredon
6.在SCshell下使用showboard-pproms查看版本
:
SC>showboards-pprom
ComponentCompatibleVersion
--------------------------
SSC0Reference5.15.3
/N0/IB6Yes5.15.3
/N0/IB8Yes5.15.3
/N0/SB0Yes5.20.11Build_01
/N0/SB2Yes5.20.0Build_15.1
/N0/SB4Yes5.15.3
:
SC>showboards-pversion-v
ComponentSegmentCompatibleInDateTimeBuildVersion
------------------------------------------------
SSC0/FP0------RTOSversion:
32
SSC0/FP1ScAppReference1209/30/200323:
0310.25.15.3
SSC0/FP1Ver--09/30/200323:
0310.25.15.3
/N0/IB6/FP0iPOSTYes1209/30/200323:
0110.25.15.3
/N0/IB6/FP0Ver--09/30/200323:
0110.25.15.3
/N0/IB8/FP0iPOSTYes1209/30/200323:
0110.25.15.3
/N0/IB8/FP0Ver--09/30/200323:
0110.25.15.3
/N0/SB0/FP0POSTYes1209/22/200804:
571.05.20.11
/N0/SB0/FP0OBPYes1209/22/200804:
561.05.20.11
/N0/SB0/FP0Ver--09/22/200804:
581.05.20.11Build_01
/N0/SB0/FP1POSTYes1209/22/200804:
571.05.20.11
/N0/SB0/FP1OBPYes1209/22/200804:
561.05.20.11
/N0/SB0/FP1Ver--09/22/200804:
581.05.20.11Build_01
/N0/SB2/FP0POSTYes1204/04/200617:
3215.15.20.0
/N0/SB2/FP0OBPYes1204/04/200617:
3115.15.20.0
/N0/SB2/FP0Ver--04/04/200617:
3315.15.20.0Build_15.1
/N0/SB2/FP1POSTYes1204/04/200617:
3215.15.20.0
/N0/SB2/FP1OBPYes1204/04/200617:
3115.15.20.0
/N0/SB2/FP1Ver--04/04/200617:
3315.15.20.0Build_15.1
/N0/SB4/FP0POSTYes1209/30/200323:
0110.25.15.3
/N0/SB4/FP0OBPYes1209/