最新耦合器测试报告

TESTREPORT

IEC60320-1and/orEN60320-1

Appliancecouplersforhouseholdandsimilargeneralpurposes

Part 1:

Generalrequirements

ReportreferenceNo.:

Testedby

(printednameandsignature):

Approvedby

(printednameandsignature):

Dateofissue:

TestingLaboratoryName:

Address:

Testinglocation/procedure:

CBTLSMTTMP

Address:

Applicant’sName:

Address:

Testspecification

Standard:

IEC60320-1:

2001and/orEN60320-1:

2001

Testprocedure:

CBand/orCCAScheme

Non-standardtestmethod:

TestReportFormNo.:

IECEN60320_1D

TRForiginator.:

IMQ

MasterTRF:

Dated02-02

Copyright©2002IECSystemforConformityTestingandCertificationofElectricalEquipment

(IECEE),Geneva,Switzerland.Allrightsreserved.

Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheIECEEisacknowledgedascopyrightownerandsourceofthematerial.IECEEtakesnoresponsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext.

Testitemdescription:

Trademark:

Manufacturer:

Modeland/ortypereference:

Rating(s):

Copyofmarkingplate

Summaryoftesting

Testitemparticulars:

Connector:

Yes/No

...whichis:

rewirable/non-rewirable

Applianceinlet:

Yes/No

...whichis:

integrated/incorporated

For:

coldconditions/hotconditions/veryhotconditions

For:

Class Iequipment/Class IIequipment

Earthingcontact:

with/without

Typeofterminal:

pillar/screw/stud/screwless

Typeofcord:

Cross-sectionalareas(mm²):

Voltage(V):

Current(A):

StandardSheet:

C

Possibletestcaseverdicts:

Testcasedoesnotapplytothetestobject:

N/A

Testitemdoesmeettherequirement:

Pass(P)

Testitemdoesnotmeettherequirement:

Fail(F)

Testing

Dateofreceiptoftestitem:

Date(s)ofperformanceoftest:

Generalremarks

ThistestreportisnotvalidasaCBTestReportunlesssignedbyanapprovedCBTestingLaboratoryandappendedtoaCBTestCertificateissuedbyaNCBinaccordancewithIECEE02.

Thetestresultspresentedinthisreportrelateonlytotheitem(s)tested.

Thisreportshallnotbereproducedexceptinfullwithoutthewrittenapprovalofthetestinglaboratory.

”(seeremark#)"referstoaremarkappendedtothereport.

”(seeAnnex#)"referstoanannexappendedtothereport.

"(seeappendedtable)"referstoatableinthereport.

Throughoutthisreportacommaisusedasthedecimalseparator.

 

IEC60320-1and/orEN60320-1

Clause

Requirement-Test

Result-Remark

Verdict

8

MARKING

8.1

Connectorsmarkedwith:

-ratedcurrent(A) :

-ratedvoltage(V) :

-symbolfornatureofsupply :

-maker'sorresponsiblevendor'snameortrademark :

-typereference :

8.2

Applianceinletsmarkedwith:

-maker'sorresponsiblevendor'snameortrademark :

-typereference(notvisible) :

8.3

ConnectorsandapplianceinletsforClass IInotmarkedwithsymbolforClass II

8.4

Correctsymbolsused

8.5

Markingeasilydiscernible

8.6

Contactpositioninnon-reversibleconnectorsshallbe:

-earthingcontact:

uppercentralposition

-linecontact:

lowerrighthandposition

-neutralcontact:

lowerlefthandposition

Indicationofterminalsinrewirablenon-reversibleconnectorsshallbe:

-earthingterminal:

[earthsymbol]:

-neutralterminal:

N :

Markingnotonremovableparts

Rewirableconnectors:

supplyedinstruction:

-methodofconnectionofconductors:

-full-scalediagram:

-sizesanstypesofcordssuitable:

8.7

Markingdurableandeasilylegible:

15 swithhexane,15 swithwater

9

DIMENSIONSANDCOMPATIBILITY

9.1

AppliancecouplerscomplywithrelevantStandardSheet :

C

9.2

RetainingdevicescomplywithStandardSheetC 25

9.3

Single-poleconnectionsnotallowed

ImproperconnectionswithplugsofIEC 83notallowed(forconnectors)

ImproperconnectionswithportablesocketoutletsofIEC 83notallowed(forapplianceinlets)

9.4

Engagementimpossibleof:

connectorsforClass IIwithapplianceinletsforotherequipment

connectorsforcoldconditionsinapplianceinletsforhotorveryhotconditions

connectorsforhotconditionsinapplianceinletsforveryhotconditions

connectorsinapplianceinletshavingahigherratedcurrent

9.5

Pinendsdonotprotrudebeyondlimitingsurfaceoftheshroud

9.6

DeviationsfromthedimensionsspecifiedinStandardSheetdonoteffectinterchangeability

10

PROTECTIONAGAINSTELECTRICSHOCK

10.1

Livepartsofapplianceinletsnotaccessible

Livepartsandearthingcontactofconnectorsnotaccessible

10.2

Connectionbetweenapinandthecontactimpossiblewhentheotherpinisaccessible

10.3

Partspreventingaccesstolivepartsonlyremovablewithatool,and

thesepartsinsulatedfromliveparts

Bushesadequatelyfixedandremovableonlywhendismantlingtheconnector

10.4

Externalpartsofconnectorsshallbeofinsulatingmaterial

Shroudandbaseofapplianceinletwithoutearthingcontactand2,5 Awithearthingcontactshallbeofinsulatingmaterial

11

PROVISIONFOREARTHING

11.1

EarthingterminalscomplywithCl. 12

11.2

Earthconnectionmadebeforeinsertionofthecurrent-carryingcontactsandbrokenafterwithdrawing

12

TERMINALSANDTERMINATIONS

12.1.1

Rewirableconnectorsprovidedwithterminalswithscrew;typeofterminals;StandardSheetNo.C :

Nonrewirableconnectorsprovidedwithsoldered,welded,crimpedorotherscrewlessconnections :

Screwedconnectionsnotused

12.1.2

Clampingmeansofterminalsshallnotservetofixanyothercomponents

12.1.3

Rewirableconnectors 16 Aterminalsize 1acceptconductorsof0,75 mm²to1,5 mm²

12.2.1

Screwtypeterminalsshallallowconnectionwithoutspecialpreparation

12.2.2

Screwtypeterminalsshallhaveadequatemechanicalstrength

ScrewsandnutforclampingtheconnectorsshallhavemetricISOthread

Screwsshallnotbeofmetalwhichissoftorliabletocreep

12.2.3

Screwtypeterminalsshallberesistanttocorrosion

12.2.4

Clampingofconductorreliableandbetweenmetalsurfaces

Pulltest(1 min):

-pull(N) :

40 N/50 N

-smallestcross-sectionalarea(mm²) :

-largestcross-sectionalarea(mm²) :

-duringthetest,conductordoesnotmovenoticeably

12.2.5

Clampingofconductorwithoutunduedamagetotheconductor;torquetest:

-torque(Nm) :

-smallestcross-sectionalarea(mm²) :

-largestcross-sectionalarea(mm²) :

12.2.6

Terminalsize:

 :

1/2

Nominalcrosssectionalarea(mm²) :

1,5 mm²/2,5 mm²

Torquetest:

conductordoesnotslipout;torque(Nm) :

12.2.7

Screwtypeterminalsdesignedsoasnottocauseexcessivetemperatures.ComplianceischeckedbythetestofCl. 21

12.2.8

Screwsandnutstightenedandloosened5 times.Duringthetest,terminalsdonotworklooseandshownodamage;torque(Nm) :

12.2.9

Screwtypeearthingterminalssamesizeasliveterminals

12.2.10

Clampingscrewsornutsadequatelylockedagainstaccidentalloosening,and

impossibletoloosenwithouttheaidofatool

12.2.11

Screwtypeearthingterminalsshallbesuchthatthereisnoriskofcorrosion

Bodyshallbeofbrassorothermetalnolessresistanttocorrosion

12.2.12

Pillarterminals,distanceg(mm)nolessthan1,5 mm(seeStandardSheetC 26) :

13

CONSTRUCTION

13.1

Forappliancecouplernoriskofaccidentalcontactbetweenearthingcontactofapplianceinletandlivecontactsoftheconnector

13.2

Fixingscrewsadequatelylockedagainstloosening

13.3

Pinsandcontactsadequatelylockedagainstrotation

13.4

Pinsofapplianceinletsshall:

besecurelyretained

haveadequatemechanicalstrength

notberemovablewithoutatool

besurroundedbyashroud

Testfornon-solidpins:

testforce100 Nfor1 min.Afterthetestnoalterationofpin

Testforsecurityofpinretention(1 h);eachpinsubjectedtoaforceof60 Nfor1 min;testtemperature(C) :

Duringthetestnomovementexceeding2,5 mm :

Afterremovaloftestforce,pinsremainwithinthetolerancesspecifiedintheStandardSheet

13.5

Contactsprovideadequatecontactpressure

13.6

Enclosureofrewirableconnectorsconsistofmorethanonepartandenclosetheterminalsandtheendsofcableorcord

Constructionsuchthatconductorscanbeproperlyconnectedandthecoresarenotpressedagainsteachother

Coreofliveconductornotincontactwithaccessiblemetalparts

Coreofearthingconductornotincontactwithliveparts

13.7

Forrewirableconnectors:

impossibletoassembletheconnectorwithterminalsenclosedbutwithcontactaccessible

13.8

Partsofthebodyofconnectorsreliablyfixed,dismantlingnotpossiblewithouttool

Independentmeansforfixingandlocatingpartsofthebody

Threadcuttingscrewsnotused

Resiliencyofthecontactsnotdependentupontheassemblyofthepartsofthebody

Partiallooseningofassemblyscrewsdoesnotallowthedetachmentofpartsprovidingprotectionagainstelectricshock

13.9

Earthingcontactfixedtothebody

Earthingcontactonepieceonlywithearthingterminal