TP14 TEST PROGRAM NUT Snow White Verion 2 update on 30Augby JFA.docx
《TP14 TEST PROGRAM NUT Snow White Verion 2 update on 30Augby JFA.docx》由会员分享,可在线阅读,更多相关《TP14 TEST PROGRAM NUT Snow White Verion 2 update on 30Augby JFA.docx(30页珍藏版)》请在冰豆网上搜索。
TP14TESTPROGRAMNUTSnowWhiteVerion2updateon30AugbyJFA
Date
POD1
POD2
Startthetest
Finishthetest
1.SCOPE
POD1&POD2testprogramofNUTSnowWhite
NUTSnowWhiteisaliquidelectricpestcontrolplug-indeviceforEuropeCountries(FR,ES,BE,CEE,NL,PT,GR).
2.PRODUCTREFERENCEPICTURES
3.TESTPROGRAM
Test
Nº
Site
Test
MEI
TestConditions
Status
P/D/T/U
Class
F/S/A
Samples
POD1/POD2
Reportnº
ResultComments
TestsResume
POD1
POD2
Test
NA/X
Result
OK/NOK
Test
NA/X
Result
OK/NOK
1
ZIS
Dimensionalreportstoallthepartsandaestheticcheck
-
20+-5ºC
N.A.
F
1xmouldcavity
AllthepartscomplywhitthedrawingDimensionsandaestheticchecks
x
x
2
ZIS
Powerinputandcurrent
IEC60335-1Part10
20±5℃
U
S
10
Actualpowerlowerthan1.20timesratedpower
(IEC60335-2-101)
x
x
3
ZIS
BallpressureTest
IEC60695-10-2
20±5℃
U
S
3
Theresult(temperature)isexpressedaspassifthediameterdoesnotexceed2.0mm
x
x
4
ZIS
GlowWireTest
IEC60695-2-11
20±5℃
U
S
3
Thedeviceisconsideredtohavepassedthetestifthereisnoflamingorglowingat650℃,orifflamesorglowingofthedeviceextinguishwithin30safterremovaloftheglowwire
x
x
5
ZIS
Normalheatingtemperaturetest
IEC60335-1Part11
20±5℃
U
S
1
Testat1.06timesratedvoltage
x
x
6
ZIS
Abnormalheating
IEC60335-1Part19
20±5℃
U
S
1
Testat0.9and1.1timesratedvoltageandwrappedwithcottonsheetatratedvoltage
x
x
7
ZIS
LeakagecurrentandelectricstrengthTest
IEC60335-1Part13&16
20±5℃
U
S
10
Noarcorbreakdownshalloccurafterapplyavoltageof3750Vbetweenexternalenclosureandlivepartsduring1minute(IECStandard3000V),Leakagecurrentshallnotexceed0.35mA
x
x
8
ZIS
MechanicalEnduranceTest
IEC60335-1Part23
20+-5ºC
U
S
10
After100timesrotations,thereshouldbenophysicaldamageandthedeviceshouldstillbefunctional
x
x
9
ZIS
0.5JImpactTest
MEI036
20+-5ºC
U
S
5
Nodamageafter3timesblowsappliedtovariouspartsontheenclosure,theimpactenergy0.5±0.4J
x
x
10
ZIS
FreeFallTest
MEI007
20+-5ºC
U
S
10
After100fallsthedeviceshallnotbedamagedtosuchandextendthatcompliancewithUL/CEIapplicablestandards
x
x
11
ZIS
PlugRotationEaseOfUseTest
MEI027
20+-5ºC
U
F
10NUTSnowWhite+10Mashdevices
Forcerequiredtorotatetheplugdeckineitherdirection≤1.5N.m(TBD)
Therotationforceshouldbeequaltothebenchmarkdevice(Mashdevice)
x
x
12
ZIS
PlugRotationExcessiveForceTest
MEI151
20+-5ºC
U
F
10
Therotatingplugdeckmustbeabletowithstandaforceofatlease1.8N.m(TBD)inbothrotationdirections.
x
x
13
ZIS
Refillscrewin&outTest
-
20+-5ºC
I
F
10
Thedevicewillbedeemedtohavepassedthetestifthe2kindofrefillbottlescanbesmoothlyscrewin&outofthedevice(GrayNeckandMashNeck)
x
x
14
ZIS
HousingSeparationTest
MEI117
20+-5ºC
U
S
12
Forcerequiredtosplittheupperandlowerhousingmust≥250N
x
x
15
ZIS
UnsnappingTest
MEI006
20±5℃
U
S
10
Thepinsandbladeshavetoresistaforcehigherthan250N
x
x
16
ZIS
CrimpingTest
MEI132
20±5℃
U
S
10
Junctionbetweenpinbridgeandwiremuststandaminimumforceof20N
x
x
17
ZIS
OvervoltageTest
-
20±5℃
U
S
6
Connectthedevicesat2xVnduring5hafterthetest
Thedevicearesafeandnotfireappears
(MeasurethemA,ohmsbeforeandafterthetest)
x
x
18
ZIS
WicktemperatureTest
MEI002
20+-5ºC
U
F
12NUTSnowWhite+12perkindofbenchmarkdevices
Measurethewicktemperatureafter60minenergizedattheratedvoltagewiththetestbench
Temperaturerange:
TBD
Benchmarkdevice:
Mashdevice,Graydevice,Smartdevice
x
x
19
ZIS
EvaporationTest
-
20±5℃
U
S
6NUTSnowWhitedevicesand6perkindofrefills,6Benchmarksamplesandrefills
SamplescamefromWICKTEMPERATURETEST
TheweightlossofNUTSnowWhitedeviceshallbematchtothebenchmarkdevice,
(Tolerance:
±5%TBD)
NUTSnowWhiteexpecteddurationinbothkindofrefills:
Bloom:
45days
Grey:
60days
Evaporationcycleis8hoursperday
Nocondensationandleakageoccurduringnormaloperation
x
N/A
20
ZIS
ProductStabilityandCompatibilityTest
Perreference
MEI108
40º±2℃
P
F
8Nutdevices
Measuretheohmnicvalueandpower.
Verifythattherefillfitsperfectlyinthedevice.
Measuresomereferencedimensions(easytomeasure)
Immersethesamples(devicesassembled)inthecorrectformulationinsideaclosedboxesandputinsideacirculatingovenat40℃,during:
2samples48hours.
2samples1week.
2samples2weeks.
2samples4weeks.
Extractthesamples,dryaccuratelyandreview:
Theohmnicvaluenotchangemorethan+-2%.
Thepowernotchangemorethan+-2%
Therefillfitperfectlyinthedevice.
nocracking
nocolorchanges
Thedimensionsnotchangemorethan+-1%
x
N/A
21
ZISQETeam
TransportTesting-VibrationTest
-
20+-5ºC
U
F
6cartons
Alldevices/contentsremainfunctionalinthereferencetestconditionandwithinproductspecification.
Nodetachedcomponents/casingsoccur.
Mainspowereddevicesmustbeelectricallysafe.
Noexcessivescuffingorwearingofthesurfaceofthedeviceoccurs.
Nowearordamagetotheinsideandoutsideoftheshippingboxesthatcompromisestheirabilitytoprotectandholdthedevice.
x
x
22
ZISQETeam
TransportTesting-CartonDropTest
20+-5ºC
U
F
6cartons
SamplescamefromVIBRATONTEST
Novisualdamagetoanydevices.
Alldevices/contentsmaintainfunctionalinthereferencetestconditionandwithinproductspecification.
Nodamagetotheinsideandoutsideoftheshippingboxesthatcompromisestheirabilitytoprotectandholdthedevice.
Slightscuffingtothesurfaceofthedeviceasaresultofthedroptestcanbeacceptable.
x
x
23
ZIS
AllthecomponentsareWEEEcompliant
WEEE
N.A.
N.A.
S
N.A.
AllthecomponentshaveWEEEcertificates
x
x
24
ZIS
AllthecomponentsareRoHScompliant
RoHS
N.A.
N.A.
S
N.A.
AllthecomponentshaveRoHScertificates
x
x
25
ZES
CBcertificationTest
-
-
U
A
10perplug+10fullrefills
CBtestincludingthenationaldifferences
(FR,ES,BE,CEE,NL,PT,GR)
x
N/A
26
ZIS
DropTest
MEI552
20+-5ºC
U
F
60
Devicewithfullrefilldroppedfromonto1.2mtotheconcreteormarblefloorthedevicemustbesafeandnolivepartscanbeaccessedaftertest.
Devicesareallowedtoincurpinbending/pindepressionbeyondthepointofuse.
Refillbottlebreakageisacceptable.
Theneckoftherefillbeingleftintactinthedeviceisnotdesirablebutisdeemedacceptable.
x
x
4.COMMENTS&ANNEXES
SAMPLESRESUMEFORINTERNALZOBELETESTINGPOD1:
Samples:
Fillthecorrectsamplesnº
200devices+40refillspereachkindofrefills
25benchmarkdevices+25correspondingrefills
6Cartonboxes
SAMPLESRESUMEFORINTERNALZOBELETESTINGPOD2:
POD2testmaximumSamplesnºnecessaryincasewerepeatallthePOD1test(thisitisdecidedafterfinishthePOD1):
Samples:
Fillthecorrectsamplesnº
150devices+40refillspereachkindofrefills
25benchmarkdevices+25correspondingrefills
6Cartonboxes
Customerspecifications:
Referencedevices(BenchMarksamples):
Grey
Mash
Smart
ZobeletestreportPDF: