偏心竖向力:
Qik,max/min=[1656.1+1.1×2.0×0.8×25+2.0×0.8×5.4]/2±(10.6-7.4×1.1)×0.6/(2×0.62)=854.4±2.05
Qik,max=856.5KN<1.2×1250=1500KN
Qik,min=852.4KN>0
满足要求。
由于有水平地震参与的组合内力与无地震内力相同,故未作验算。
B.承台计算(CT2):
(1)、承台受弯承载力验算:
x方向上自桩中心到最远墙(柱)边的水平距离:
xi=0.35m
My=1.35×(1656.1/2+2.05)x0.35=392.2KN·m
A=392.2×106/(800×10502)=0.445
C30.HRB335级.ρ=0.151%<ρMIN=0.2145%
AS=0.2145%×800×1100=1888mm2
取6Φ22@150(2280mm2)
(2)、承台受冲切承载力验算:
a.柱对承台的冲切验算:
由于桩布置在柱下,且在冲切锥之内,柱对承台冲切无需验算。
b.角桩对承台的冲切验算:
扣除承台和其上填土自重后的角桩桩顶相应于荷载效应基本组合时的竖向力设计值:
Nl=1.35×(2235.7/2+2.05)
=1511.9KN
C1=C2=400+200=600
x方向上自桩内边缘到最近墙(柱)边的水平距离:
a1x=150mm
λ1x=a1x/ho=150/(1100-50)=0.143<0.2,λ1x=0.2
x方向上冲切系数β1x=0.56/(λ1x+0.2)
β1x=0.56/(0.2+0.2)=1.4
y方向上自桩内边缘到承台顶450斜线交点的水平距离:
a1y=Min{400-200,ho}=Min{200,1050}=200mm,
λ1y=a1y/ho=200/(1100-50)=0.190<0.2,λ1y=0.2,a1y=0.2ho=210mm
y方向上冲切系数β1y=0.56/(λ1y+0.2)
β1y=0.56/(0.2+0.2)=1.4
取ft=1.43h0=1050βhp=0.975
β1x(C2+0.5×a1y)βhpfth0+β1y(C1+0.5×a1x)βhpfth0
=1.4×(600+0.5×210)×0.975×1.43×1050
+1.4×(600+0.5×150)×0.975×1.43×1050
=2828.3KN>Nl,满足。
(3)、承台斜截面受剪承载力验算:
V=1.35×(1656.1/2+2.05)=1120.6KN
ax=150mmλx=150/1050=0.143<0.3,取0.3
β=1.75/(λ+1.0)=1.75/(0.3+1.0)=1.35
βhs=(800/1050)1/4=0.93
βhsβftb0h0=0.93x1.35x1.43x800x1050=1508.1KN>V
满足
(4)、承台局部受压承载力验算:
由于上部墙柱砼强度等级C35大于承台砼强度等级C30,故须进行墙柱下承台的局部承压验算以及验算桩上承台的局部受压承载力,
a.桩上承台局部受压承载力验算
Al=3.14×4002/4=125600mm2
Aln=3.14×(4002-2102)/4=90981.5mm2
Ab=3.14×12002/4=1130400mm2
ßl=(Ab/Al)1/2=(1130400/125600)1/2=3
ßc=1.0
1.35ßcßlfcAln=1.35×1.0×3×14.3×90981.5=5269.2KN>1.35Qik,max=1.35x856.5
=1156.3KN
满足
b.柱下承台局部受压承载力验算
局部压力设计值Fl=Nmax=2235.7KN
局部受压面积AL=500x500=250000mm2
柱下承台局部受压计算底面积:
Ab=1000x800=800000mm2
ßl=(Ab/Al)1/2=(800000/250000)1/2=1.79
ßc=1.0
1.35ßcßlfcAln=1.35×1.0×1.79×14.3x250000=8639KN>Fl
满足
六桩
3-7轴—3-F轴的两片剪力墙:
有水平地震参与的组合内力(基本组合):
Nmax=10099.2KN
MX=491KN·mMy=-22.4KN·m
Vx=18.6KNVy=597.8KN
按GB50007-2002第3.0.5条
Nmaxk=7480.8KNMXk=363.8KN·mMyk=-16.6KN·m
Vxk=13.8KNVyk=442.8KN
n=[7480.8+1.1×2.0×3.2×25+3.2×2×5.4]/(1.25×1250)=4.9取n=6
单桩承载力计算:
轴心竖向力:
Qk=(Fk+Gk)/n=[7480.8+1.1×2.0×3.2×25+3.2×2×5.4]/6=1281.9kN<1.25Ra=1.25×1250.0=1562.5kN
偏心竖向力:
Qik,max/min=[7480.8+1.1×2.0×3.2×25+3.2×2×5.4]/6±(363.8-442.8×1.1)×1.2/(6×1.22)=1281.9±17.1
Qik,max=1299.0KN<1.2×1.25×1250=1875KN
Qik,min=1264.8KN>0
满足要求。
由于无水平地震参与的组合内力比有地震内力有利,故未作验算。
B.承台计算(CT20):
(1)、承台受弯承载力验算:
x方向上自桩中心到最远墙(柱)边的水平距离:
xi=0.212m
My=1.35×3×(7480.8/6+17.1)×0.212=1085.2KN·m
A=1085.2×106/(3200×10502)=0.308
C30.HRB335级.ρ=0.104%<ρMIN=0.2145%
AS=0.2145%×3200×1100=7550mm2
取22Φ22@150(8360mm2)
(2)、承台受冲切承载力验算:
a.墙对承台的冲切验算:
由于桩布置在墙下,且在冲切锥之内,墙对承台冲切无需验算。
b.角桩对承台的冲切验算:
扣除承台和其上填土自重后的角桩桩顶相应于荷载效应基本组合时的竖向力设计值:
Nl=1.35×(7480.8/6+17.1)
=1706.3KN
Nl≤[β1x(C2+0.5×a1y)+β1y(C1+0.5×a1x)]βhpfth0
C1=C2=400+200=600
y方向上自桩内边缘到承台顶450斜线交点的水平距离:
a1y=1050mmλ1y=a1y/ho=1050/(1100-50)=1.0
y方向上冲切系数β1y=0.56/(λ1y+0.2)
β1y=0.56/(1.0+0.2)=0.467
x方向上自桩内边缘到最近墙(柱)边的水平距离:
a1x=12mm,λ1x=a1x/ho=12/(1100-50)=0.01<0.2
λ1x=0.2,a1x=0.2ho=210mm
x方向上冲切系数β1x=0.56/(λ1x+0.2)
β1x=0.56/(0.2+0.2)=1.4,取ft=1.43h0=1050βhp=0.975
[β1x(C2+0.5×a1y)+β1y(C1+0.5×a1x)]βhpfth0
=[1.4×(600+0.5×1050)+0.467×(600+0.5×210)]×0.975×1.43×1050
=2788KN>Nl,满足。
(3)、承台斜截面受剪承载力验算:
V=3x1.35×(7480.8/6+17.1)=5118.8KN
ax=12mmλx=12/1050=0.01<0.3,取0.3
β=1.75/(λx+1.0)=1.75/(0.3+1.0)=1.35
βhs=(800/1050)1/4=0.93
βhsβftb0h0=0.93x1.35x1.43x3800x1050=7163.5KN>V
满足
(4)、承台局部受压承载力验算:
由于上部墙柱砼强度等级C35大于承台砼强度等级C30,故须进行墙柱下承台的局部承压验算以及验算桩上承台的局部受压承载力,
a.桩上承台局部受压承载力验算
Al=3.14×4002/4=125600mm2
Aln=3.14×(4002-2102)/4=90981.5mm2
Ab=3.14×12002/4=1130400mm2
ßl=(Ab/Al)1/2=(1130400/125600)1/2=3
ßc=1.0
1.35ßcßlfcAln=1.35×1.0×3×14.3×90981.5=5269.2KN>1.35Qik,max=1.35x1299
=1753.7KN
满足
b.柱下承台局部受压承载力验算
局部压力设计值Fl=Nmax=10099.2KN
局部受压面积AL=1260000mm2
柱下承台局部受压计算底面积:
Ab=3712500mm2
ßl=(Ab/Al)1/2=(3712500/1260000)1/2==1.72
ßc=1.0
1.35ßcßlfcAln=1.35×1.0×1.72×14.3x1260000=41837.8KN>Fl
满足
六桩
3-7轴—3-B轴的两片剪力墙:
无水平地震参与的组合内力(基本组合):
Nmax=8964.8KN
Mx=-248KN·mMy=-9.6KN·m
Vx=7.8KNVy=-175KN
(翼墙的弯矩、剪力相对较小,未考虑)
按GB50007-2002第3.0.5条
Nmax=6640.6KNMxk=-183.7KN·mMyk=-7.1KN·m
Vxk=5.8KNVyk=-129.6KN
n=[6640.6+1.1×8.9×25+8.9×5.4]/1250=5.5取n=6
单桩承载力计算:
轴心竖向力:
Qk=(Fk+Gk)/n=[6640.6+1.1×8.9×25+8.9×5.4]/6=1155.6kN偏心竖向力:
Qik,max/min=[6640.6+1.1×8.9×25+8.9×5.4]/6±(-183.7+129.6×1.1)×0.35/(4×0.352)
=1155.6±29.4
Qik,max=1185KN<1.2×1250=1500KN
Qik,min=1126.2KN>0
满足要求。
由于有水平地震参与的组合内力比无地震内力有利,故未作验算。
B.承台计算(CT21):
(1)、承台受弯承载力验算:
x方向上自桩中心到最远墙(柱)边的水平距离:
xi=0.35m
Mx=2X8964.8/6x0.35=1045.9KN·m
A=1045.9×106/(5475×10502)=0.173
C30.HRB335级.ρ=0.058%<ρmin=0.2145%
AS=0.2145%×5475×1100=12918mm2
取37Φ22@150(14060mm2)
(2)、承台受冲切承载力验算:
a.墙对承台的冲切验算:
由于桩布置在墙下,且在冲切锥之内,墙对承台冲切无需验算。
b.角桩对承台的冲切验算:
扣除承台和其上填土自重后的角桩桩顶相应于荷载效应基本组合时的竖向力设计值:
Nl=1.35×(6640.6/6+29.4)
=1533.8KN
C1=638+200=838,C2=400+200=600
x方向上自桩内边缘到承台顶450斜线交点的水平距离:
a1x=1050mm
a1x=1050mm,λ1x=a1x/ho=1050/(1100-50)=1.0
x方向上冲切系数β1x=0.56/(λ1x+0.2)
β1x=0.56/(1.0+0.2)=0.467
y方向上自桩内边缘到最近墙(柱)边的水平距离:
a1y=150mm,λ1y=a1y/ho=150/(1100-50)=0.143<0.2
λ1y=0.2,a1y=0.2ho=210mm
y方向上冲切系数β1y=0.56/(λ1y+0.2)
β1y=0.56/(0.2+0.2)=1.4,取ft=1.43h0=1050βhp=0.975
[β1x(C2+0.5×a1y)+β1y(C1+0.5×a1x)]βhpfth0
=[0.467×(600+0.5×210)+1.4×(838+0.5×1050)]×0.975×1.43×1050
=3275.5KN>Nl,满足。
(3)、承台斜截面受剪承载力验算:
V=2x8964.8/6=2988KN
ay=225mmλy=150/1050=0.143<0.3,取0.3
β=1.75/(λ+1.0)=1.75/(0.3+1.0)=1.35
βhs=(800/1050)1/4=0.93
βhsβftb0h0=0.93x1.35x1.43x5475x1050=10321KN>V
满足
(4)、承台局部受压承载力验算:
由于上部墙柱砼强度等级C35大于承台砼强度等级C30,故须进行墙柱下承台的局部承压验算以及验算桩上承台的局部受压承载力,
a.桩上承台局部受压承载力验算
Al=3.14×4002/4=125600mm2
Aln=3.14×(4002-2102)/4=90981.5mm2
Ab=3.14×12002/4=1130400mm2
ßl=(Ab/Al